Model 7501T8 is a solid-state relay (SSR) rack that accommodates up to eight G4 type SSR modules. It has a 50-pin header which is compatible with several Sensoray GPIO products, including models 826 and 2410.
#REDIRECT [[7501Tx relay racks]]
 
[[Category:Products]]
==Pinout==
 
{| class="wikitable"
! SSR
! Header<br>Pin
! Terminal<br>Block Pins
! Model 826<br>J3 GPIO
! Model 826<br>J4 GPIO
! Model 2410<br>GPIO
|-
|0
|47
|1-2
|0
|24
|17
|-
|1
|45
|3-4
|1
|25
|19
|-
|2
|43
|5-6
|2
|26
|21
|-
|3
|41
|7-8
|3
|27
|23
|-
|4
|39
|9-10
|4
|28
|9
|-
|5
|37
|11-12
|5
|29
|11
|-
|6
|35
|13-14
|6
|30
|13
|-
|7
|33
|15-16
|7
|31
|15
|}
 
==Using with model 826==
 
{| class="wikitable" style="float:right"
|+GPIO mapping
! rowspan="2"|SSR
! colspan="2"|826 GPIO
|-
! J3
! J2
|-
|0
|0
|24
|-
|1
|1
|25
|-
|2
|2
|26
|-
|3
|3
|27
|-
|4
|4
|28
|-
|5
|5
|29
|-
|6
|6
|30
|-
|7
|7
|31
|}
 
The relay rack can be connected to header J3 or J2 on the 826 board.
 
You must supply 5 VDC power to the relay rack. This can be done in either of the following ways:
* Connect an external 5 VDC power source to the relay rack's +5V and GND terminals.
* Attach a wire on the bottom of the relay rack (via solder) from the +5V terminal to J1 pin 49.

Latest revision as of 14:28, 19 February 2019

Redirect to: